--------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C4A00000 Date: 04/03/95 From: ROELAND JANSEN Time: 06:55am \/To: SANDER BOEKEE (Read 5 times) Subj: new zyxel model 2864 > Has the new zyxel ISDN model an A/B convertor or an 2 A/B > convertor ? if I knew the difference :-) -- it would have an a/b interface. that is what the specs said. --- FastEcho v1.42b6+ * Origin: [PC-MOS/386 operating system support] (2:2802/105.1) --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C4A00001 Date: 04/01/95 From: MAREK DROBNIK Time: 04:20pm \/To: ALL (Read 5 times) Subj: busy tone I have a usr sporter 14.4k and I was wondering if I can make it reactances a busy tone the first time. --- Maximus 2.02 * Origin: The Sarcastic Cow,Ottawa,Canada:2.5gigs&5lines (1:163/273) --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C4A00002 Date: 04/03/95 From: ANDY MILLON Time: 05:34am \/To: PATRICK WHITE (Read 5 times) Subj: Re: FD Zyxel Init 1/2 -=> Patrick White said to Anyone, All on 04-01-95 16:26 <=- PW> I have recently been running US Robotics 14.4 with no problems. I PW> have now switched to Zyxel U-1496E (don't ask me why), and I can call PW> other bbs'from Telix, but I cannot poll any systems from Frontdoor. It PW> doesn't seem to want to work with my BBS. The robotics worked PW> flawlessly. I have not changed anything in the modem setup in FDsetup. PW> Does anyone have or know of an init string or setup for FD that will PW> work with this Zyxel. When I poll, the modem connects at 38400, but PW> then it hangs up, and later redials, hangs up...... HELP!! If you're using FD2.02nc, try the following. Modify according to your needs/setup. +++++++++++++++++++++++++ Message #1852 - NET202_SYSOP Date: 06-11-93 03:46 From: Steve Haisha To: Victor O'Rear Subject:: ZyXEL / FD Init Strings ---------------------------------------------------------------------------- Hello Victor! Friday June 04 1993, Victor O'Rear writes to All: VO> Reciently I saw some suggested ZyXEL Init strings, but they were for VO> terminals not Mailers and not complete as I saw. VO> Could someone please post a good Init string, I'm getting occational VO> lost connections from someone trying to connect. (Although only VO> 0 or 1 lost connection according to FrontDoor). YUP !!!!!! Give this a try.... ****************************************************************************** FrontDoor Setup for the The ZyXel Brand of Modems ****************************************************************************** First you need to go into FrontDoor's configuration setup.... Make these changes Modem Messages 300 CONNECT| 1200 CONNECT 1200/ 1275 CONNECT FAX <--------- 2400 CONNECT 2400 This is where you need to 4800 CONNECT 16800 <--------- make some changes, you could 9600 CONNECT 9600 also us the 38400 spot for 19200 CONNECT 19200 the 16800. 38400 CONNECT 38400 Error ERROR Terminal ͸ External mail String Level 1 ZyXEL 209 <-------- This s 2 0 the ErrorLevel I 3 0 use. 4 0 Terminal ͸ Errorlevels 300 211 1200 211 1275 209 <-------------- 209...Cool number Huh ! |:-)) 2400 211 ( Look Above ) Modem ͸ Command strings Escape code +++ Return on-line ~ATO0| Onhook ATH0M1| <---| Offhook ATH1M0| <---| Dial ATDT Prefix Set These Too. Suffix | Delay 7 Init-1 ATZ0| <----| Init-2 ATX7#B1+FCLASS=6| <----| Init-3 Down ATH1M0| Reset AT| ; ... *NO CARRIER* -- A Naval Aviator's worst nightmare! --- FMail/386 0.98 * Origin: Ready Room [SAN] 619-673-4016 v32b/v42b/fax (1:202/519.0) --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C4A00003 Date: 04/03/95 From: ANDY MILLON Time: 05:06am \/To: PATRICK WHITE (Read 5 times) Subj: Re: FD Zyxel Init 2/2 Now we need to go into your Fdbbs.bat file and set the error levels so FrontDoor can do it's thing..... These are some simple subroutines that should be in your batch file to keep it all working fine and dandy... |: - )) :Top SETLOCAL PATH D:\FD;D:\bats;D:\RA;D:\RA\MISC;C:\UTIL\ARC;C:\DOS;C:\UTIL\NC; VERIFY OFF rem tame-res iff "%_dv" == "1" then xu DV:ON ^ xu PORT:1:ON else xu PORT:1:ON endiff SET FD=D:\FD SET FDOPT=INTL SET RA=D:\RA SET GE=D:\FD SET DSZPORT=2 SET DSZLOG=D:\RA\DSZ.LOG SET TZ=PST8 SET ALLFIX=D:\FD\ALLFIX loadbtm on :Start cls d:\fd\ fd.exe /l:door if ErrorLevel 211 goto BBS_Start if ErrorLevel 210 goto Answer if ErrorLevel 209 goto ZyXEL if ErrorLevel 208 goto SendFax if ErrorLevel 200 goto Local_bbs if ErrorLevel 199 goto GechoSetup :ZyXEL pushd d:\ZyXel\receive\ Echo =========== F A X IN ================= loadbtm off d:\ZYXEL\rcvfax 2 /p:1 /w:\zyxel\receive\ loadbtm on call logf /f ============= FAX IN ================= HARVEY\ H fax.h goto start I have added this to be able to send a Fax out without taking FrontDoor down, you will exit on a ErrorLevel..208 as seen above in the patches from my batch file. :SendFax pushd d:\ZyXel\ Echo ============== S E N D F A X ================ ZFAX.com popd goto start Now ! I am not sure if you setup the function keys in FD so I guess That is where we are headed next, this will allow you to utalize the ErrorLevels that we have setup so far, along with some you may want to do in the future. Mailer ͸ Miscellaneous Log File requests FDServer External mail Display Colors Hidden dial info Function keys < ----- ok go into this option F Errorlevels Audio control 9 Swapping Protection ; Now this is what mine looks like... Mailer ͸ Miscellaneous Log Function keys Shift F1 RAMAIL F1 Nightly Maintenance F2 F2 Iceman BBS - Local F3 McFreq F3 F4 F4 F5 F5 F6 Time Set F6 F7 F7 F8 RA Configurations F8 F9 GEcho Setup F9 F10 Unpack Mail F10 Send A Fax F11 Telix F11 Answer Program--beta test F12 Roboterm F12 receive fax ; You need to edit the function keys... I will show you how to do one of them, I believe the send fax is a good one... Mailer ͸ Miscellaneous Log Shift F10 Title Send A Fax Action ?208 Remember, the ? has to be there, tells FD that you are Pause No using an ErrorLevel. Check No ; My current NRAM settings are................... AT&V0 Current Settings............ B0 E1 L0 M1 N7 Q0 V1 X7 <----- I use X7, so change that too. &B1 &C1 &D2 &G0 &H3 &J0 &K4 &L0 &M0 &N0 &P0 &R1 &S0 &X0 &Y1 *B0 *C0 *D0 *E0 *F0 *G0 *I0 *L0 *M0 *P9 *Q2 *S0 S00=000 S01=000 S02=043 S03=013 S04=010 S05=008 S06=003 S07=060 S08=002 S09=006 S10=007 S11=070 S12=000 S13=000 S14=002 S15=002 S16=000 S17=018 S18=000 S19=000 S20=002 S21=178 S22=000 S23=121 S24=014 S25=000 S26=000 S27=156 S28=068 S29=000 S30=000 S31=017 S32=019 S33=255 S34=030 S35=000 S36=000 S37=000 S38=000 S39=000 S40=000 S41=000 S42=000 S43=000 S44=000 S45=100 S46=028 S47=064 S48=000 S49=000 S50=000 S51=000 S52=000 S53=000 S54=000 S55=000 S56=000 S57=000 S58=000 S59=000 I guess that is it for now.... Good Luck and happy modeming. /r Steve " The ICEMAN " --o-- * Origin: >>*<< ICEMAN BBS (619)442-7552 >>*<< ZyXel U-1496E+ (1:202/1506) --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C4A00004 Date: 04/02/95 From: JIMMY WONG Time: 10:54am \/To: ALL (Read 5 times) Subj: ISDN Hello, Can anyone can fully explain with me what is ISDN (NT-1 interface) ?....etc. I want to know more about this. Thank you very much. Jimmy Wong --- GEcho 1.11+ * Origin: We will be a friends ? (1:124/7006.6) --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C4A00005 Date: 04/03/95 From: KEN SCHAFER Time: 05:05pm \/To: GREG MCCARTHY (Read 5 times) Subj: Ping Hello Greg. In a message to Marino Schwedhelm you wrote: MS> Is someone reading this or is the echo dead? Please send netmail. x GM> I think you and I are the only ones connected...there hasn't GM> been any mail in here for quite a while. Nope, I've got one of these beauties too and read this echo regularly. Pity about ZyXELNet going down so badly - it was a very useful network once upon a time. Take care. Ken. --- FMail 0.98+ * Origin: The Baudwalk - Cape Town, South Africa (5:7102/132) --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C4A00006 Date: 04/03/95 From: CRAIG SAVAGE Time: 05:05pm \/To: ALL (Read 5 times) Subj: Wanted - 28.8k Zyxel Voice/FAX/modem Could anyone out there help me find someone who sells Zyxels ? I would like the 28.8k but will settle for a 19.2k new or second hand. Contact me on (011)886-1738 if u can help. Thanx Craig Savage --- FMail 1.00G+ * Origin: Top Byte - VWBurg, South Africa - 1Gig - (5:7106/37) --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C4A00007 Date: 04/02/95 From: JESPER NICK JRGENSEN Time: 11:08pm \/To: ALL (Read 5 times) Subj: Up 2 date Hello All! What is the most recent release version of: __ ZYXEL 1496 firmware __ ZFAX Can I expect my 1496E+ to become compatible with 19k2 Terbo in the future? Shouldn't I be able to go 76800 between ZYXEL and my PC's 16550? Does ZYXEL have an Internet site? Jesper --- GEcho 1.00 * Origin: Very funny Scotty, now beam down my clothes! (2:235/90.55) --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C4A00008 Date: 04/02/95 From: HENK HEIDEMA Time: 08:28pm \/To: KARI TIIHONEN (Read 5 times) Subj: Cebit 95 On 28 Mar 95 18:04:00 Kari Tiihonen wrote a message to Henk Heidema on the subject "Cebit 95". > Here in Europe V.34 is a dying protocol... Living in an other part of europe and the Telco still charges extra for an ISDN2 line. Henk --- * Origin: Develsteyn Castle [OS/2] +31 78 200422 (2:285/304)