--------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C3I00006 Date: 03/11/95 From: TONY IRONSIDE Time: 10:03am \/To: DAVE LYLE (Read 4 times) Subj: 28.8 modems ? DL> (( On 03-03-1995, Tony Ironside wrote to Styx Allum: )) TI> SA> V6.00 EPROMs, but I've reprogrammed them with V6.14... TI> SA> and still I can't get the CALLER ID to work reliably. TI> SA> Every once in a while, it will respond to an "ANONYMOUS" call TI> SA> (i.e. "REASON FOR...: PRIVACY") and ONCE it reported a name. TI>If you are in Canada, you have to send it in to get TI>the "Canadian Caller ID TI>Fix" it's free, you just have to pay shipping.... DL> It's not just for Canada anymore . I too had to add the capacitor DL> to get my U-1496B v6.14 working with caller ID. Surprisingly, ZyXel DL> tech support told me how to do it myself (over the phone). It's a DL> .033 uF cap soldered in parallel with R4. R4 is a 10K 1/4W res located DL> near the input line relay and transformer. DL> WARNING! Note that doing this yourself may void the warranty. I guess I will not do it myself then :) I want to be able to trade it in for the 28.8's when they finally get released..... Tony --- Maximus/2 2.02 * Origin: Get A Grip OS/2 (1:134/223) --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C3I00007 Date: 03/12/95 From: STEVE SHARP Time: 03:30pm \/To: STYX ALLUM (Read 5 times) Subj: V6.14 ROMS G'Day Styx.. > Is it just me or has everybody's on-line help disappeared from their > Zyxel with the release of the 6.14 ROMS? SA> "It's just you." ;-) > My 1496E+ now reports "Please refer to chapter 6, 7 and 8 of user > manual" when I hit it with an AT$. SA> Here's what my U1496B says: SA> ati1 SA> 21071 SA> U1496B V 6.14 SA> OK SA> at$ SA> Basic Command Summary SA> &$ Extended Command Summary I0 Product Information Interesting (and curious) that the B version of 6.14 keeps the on-line help and the E+ looses it? I wonder if all + models lost the on-line help and the standard models kept it? Wonder if ZyXEL just downright forgot? > # Origin: Palantir BBS - Smoke Alarms Save Lives! (3:714/207) SA> Wow. We used to have a board here in Eugene, Oregon named "Palantir". SA> Hard to be original, I guess. ;-) SA> -Styx Maybe, but according to the book there were 3 Palantirs;-) Cheers, Steve --- OPMED/SQ 3.20wb * Origin: Palantir BBS - Smoke Alarms Save Lives! (3:714/207) --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C3I00008 Date: 02/28/95 From: DAMJAN MURKO Time: 11:13am \/To: MARTIN BELANGER (Read 4 times) Subj: Re: Win ? MB> Hello Damjan! MB> Sunday February 12 1995 18:55, Damjan Murko wrote to All: DM> Hello! DM> Has anyone been testing SuperVoice 2 For Windows or similar product. DM> I would desperatly like to know results. MB> It works... but I don't like it. It takes too much time to prepare a ... MB> little message editor. Like I can see, you are not satisfied with it. Perhaps I will gotta die with fact that there isn't any program for FAX/BBS/Voice for windows. MB> The most important thing... I HATE Windows!!! Well, from now one I am with you. MB> Martin (ZyXEL authorized reseller) ZuTSR Registering & Support Site So, even dealers could not get right kind of software. uf.. BTW: From where are you? Greetings (Sory about bad english) DM,inc. ... DaMage, inc. ...now you know me! (2:380/121) ___ DaMaged QWK 2.12 --- FidoPCB v1.5 beta-'j' * Origin: * Marand BBS * Ljubljana, SLO * +386-61-1232414 * (2:380/121) --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C3I00009 Date: 03/13/95 From: KOLJA WASCHK Time: 12:31am \/To: BERTUS DE WET (Read 4 times) Subj: Voice Cmds For Zyxel's BDW> Could anybody please tell me what the AT commands for a BDW> XYZEL-modem for the following are: (in VOICE MODE) "ZyXEL", not XYZEL ;-) Please request all or selected ones of the following files from my BBS to get information about the voice mode. There are not always really appropriate commands for all things you requested, so getting a full doc would be more helpful for you than just guesses by me about what you possibly meant in particular... What modem or description did you take for building your command request list ? All of the following files contain at least a part of the necessary information about the ZyXEL's voice mode. I suggest you request the ones marked with an asterisk (*). The 6.xx numbers refer to firmware revision numbers (6.14 is the actual one). If you cannot display Windows .WRI format, get VOICE.UPD instead of MANUAL.ZIP. Most major changes happened between 6.00 and 6.14, so MANUAL.ZIP is not necessarily a better base than VOICE.UPD. BISYNC.ZIP 1k (*) (bisync protocol description, ASCII) MANUAL.ZIP 110k (*) (manual revision 2.2 up to 6.10, *.WRI format) ATQR613.ZIP 75k (quick reference 6.13, Encap.Postscript) QUICKREF.ZIP 12k (quick reference 6.00, ASCII) VOICE.UPD 25k (voice commands 5.xx, ASCII) 600-614.ZIP 18k (*) (release notes firmware 6.00 .. 6.14, ASCII) BTW, I also have a documentation for the Rockwell voice command set, which is quite similar to ZyXEL's (despite some minor parameter and spelling differences) : RVOICE.ZIP 40k (rockwell voice AT command set) If you need more info about ZFax/ZUtil/VoiceConnect voice file format/coding, ask, I have some infos about this. I cannot give information about Rockwell ADPCM encoding (NDA). Note the new phone number for the BBS (below). It's not in the nodelist.062, but hopefully will be updated in .069. K.Waschk e-mail:kawk@Yo.COM --- timEd 1.00+ * Origin: new: +49-40-88913035,ZYX,ISDNA-C (2:240/5533) --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C3I00010 Date: 03/13/95 From: TONY IRONSIDE Time: 10:52am \/To: STYX ALLUM (Read 4 times) Subj: 28.8 modems ? Hello Styx! 12 Mar 95 16:20, Styx Allum wrote to Tony Ironside: >>>> If you are in Canada, SA> [...] >>SA> Nope. I'm in Oregon. SA> [...] >> I'll shut up now :) SA> No problem. If I ever leave Oregon for Canada, the ZyXEL will SA> too. [heh] Read back a couple of messages, supposedly the caller id fix, is also for the states too :) some guy posted how to fix it.... Tony --- GoldED/2 2.42.G0615 * Origin: GET A GRIP -=254-9466=- (1:134/223) --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C3I00011 Date: 03/05/95 From: JERRY SCHWARTZ Time: 12:30pm \/To: GLEN GILBERT (Read 4 times) Subj: HELP!! On Mar 02, Glen Gilbert (1:157/534@fidonet.org) told Michael Yin... GG> In case you are using Binkley as a front end.. GG> ;Binkley can't tolerate '.' as in S40.2=1 - use S40=4 instead ;Binkley will escape a '.' as in S40\.2=1 --- msged 2.07 * Origin: Write by Night, New Britain CT, USA (1:142/928@fidonet.org) --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C3I00012 Date: 03/13/95 From: FILIPE SILVA Time: 03:24pm \/To: ALL (Read 4 times) Subj: Speed problems - Help! I have a ZyXel u-1496E and I notice that I see to get better transmission speed when I dial at 9600 rather than 19.2. Does anyone have an explanation? Can I get a faster connection? Thankx! Filipe. ... Open mouth, insert foot, echo internationally. --- RA 2.02 * Origin: Lava Rock 16.8K V32b ZyXel (905)566-8518 (1:259/438) --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C3J00000 Date: 03/11/95 From: LENNART EINARSSON Time: 11:06am \/To: CHRIS ROBERTS (Read 4 times) Subj: Re: ? * Quoting Chris to * * On subject at 03-06-95 18:52 * CR> Chris Roberts - chris.roberts@swamp.mn.org - All Mail Welcome And? /Lelle ___ Blue Wave/QWK v2.12 --- EzyQwk V1.10g3 03fa0001 * Origin: Not tonight dear, I have a ZyXEL E+ (2:201/2129) 602 610 619 204/0 400 205/0 206/0 --------------- FIDO MESSAGE AREA==> TOPIC: 116 ZYXEL MODEMS Ref: C3J00001 Date: 03/11/95 From: ROBERT BLEUMER Time: 07:30am \/To: ALL (Read 4 times) Subj: ZyXEL v.34 upgrade ============================================================================= * Forwarded by Robert Bleumer (2:284/608) * Area : ZYXEL.028 (FIDO-NL : Zyxel Area) * From : Robert Udo, 2:283/410 (Friday March 10 1995 01:09) * To : All * Subj : ZyXEL v.34 upgrade ============================================================================= Trade In/Add-On Basisprijzen: (in DM (naar een Dollarkoers van 19-07-94) ----------------------------- Model EG+ EG S+/S E+ E B+ B